Discussion Central

Expand all | Collapse all

Anti explode Design For fixed-bed reactor

  • 1.  Anti explode Design For fixed-bed reactor

    SENIOR MEMBER
    Posted 06-26-2018 21:49
    Hi guys, along with environmental challenges, the reactor need to be anti-explode designed instead of relief design. Are you willing to provide this information for me?

    ---------------------------------
    Han Li
    vice chief engineer
    Hualu
    ---------------------------------


  • 2.  RE: Anti explode Design For fixed-bed reactor

    Posted 06-28-2018 01:53
    Hi,

    What is the reaction? Temperature? Pressure?

    ---------------------------------
    Ali Golshanabadeh MS
    Process Engineer
    BASF
    Corpus Christi TX
    ---------------------------------





  • 3.  RE: Anti explode Design For fixed-bed reactor

    SENIOR MEMBER
    Posted 29 days ago
    PA reactor , pressure 0.6barg, temp. 360degree C salt bath. hot point temperature 450degree C.

    ---------------------------------
    Han Li
    project manager
    Hualu
    Xi'an
    ---------------------------------